Air con unit 0 3 meter from rear of servers they have asked if we can have some sort of lining thrown over the carpet as it is a rented building.
Carpet in a server room.
Therefore dozens of data lines that are entering each server must also be accessed.
Today s computer room flooring design focuses on optimizing connectivity and cable distribution.
Data centers and server rooms without raised floors are perceived as being incomplete or less than state of the art.
I just started a new job and the server room has an organized server rack however it is bolted to and below the carpet.
For many companies the presentation of their server room is an important part of facility tours for key customers.
Contamination control mats help ensure that dust carpet fibers and other small particulate are not tracked into the room via people s shoes or wheels on carts.
Not only are carpets hazardous to the electronics directly they re at a greatly increased risk of catching fire in the event of catastrophic equipment failure when compared to other flooring options.
Ive requested the carpet to be removed from my server room a disaster was almost waiting to happen air con leaked and the carpet under the rack was soaked.
If your current server room is carpeted and removing it is not an option at this time it s highly recommended that you at least cover the.
The choice of anti static flooring for a data center involves a number of considerations but the single most important factor is the type of footwear people will be wearing while working in the data center.
The carpet is glued to the floor so if we remove it there will be glue spots on the floor and i m.
Place contamination control mats at all entrances to the computer room.
A server room raised floor creates a strong framework of 24 inch by 24 inch panels positioned at heights between 3 inches and 6 feet off the ground.
I am worried about static problems since we will be adding more mission critical servers to the rack.
The room is on the second floor of the building and was previously used as an office.
Maintain positive air pressurization in the computer room relative to surrounding areas.
Server room raised floors are the hallmark of the high availability enterprise data center and with good reason.
In most situations footwear cannot be controlled in data centers.
Many rack systems constantly change wiring requirements.
For this reason it is always recommended that you select your floor with the premise that the floor must prevent static.
The room is only small but should hold upto 6 racks with room to move but initially there will only be 1 rack.